2250mm热连轧F7精轧出口上卫板结构改进
引用本文:王金伟. 2250mm热连轧F7精轧出口上卫板结构改进[J]. 机械工程与自动化, 2012, 0(3): 184-185
作者姓名:王金伟
作者单位:太原钢铁(集团)有限公司热连轧厂,山西太原,030008
摘    要:介绍了太钢2 250 mm热连轧F7精轧机出口导卫,分析了由于带钢板型不好,频繁发生带钢翘头顶断出口上切水板造成废钢的故障.通过对出口上卫板及切水板的结构改进,彻底解头了这一难题,取得了良好的经济效益.

关 键 词:热连轧  精轧机  出口上卫板  切水板

Improvement of Top Guide Plate at Exit of F7 of 2 250 mm HSM in TISCO
WANG Jin-wei. Improvement of Top Guide Plate at Exit of F7 of 2 250 mm HSM in TISCO[J]. Mechanical Engineering & Automation, 2012, 0(3): 184-185
Authors:WANG Jin-wei
Affiliation:WANG Jin-wei(Hot Strip Mill of Taiyuan Iron & Steel(Group) Co.,Ltd.,Taiyuan 030008,China)
Abstract:In case of unsatisfactory strip flatness,it happens that the turned-up head hits and breaks the top wiper at the exit of F7 and consequently causes the trouble.Due to the fact that it takes long time to remove the trouble and difficult to repair or change the wiper,the accident impairs the production and brings huge loss.The article clarifies how to solve the problem by improving the structure of the top guide plate with the wiper at the exit of F7.
Keywords:hot strip mill  finishing mill  exit top guide plate  wiper