Determination of the235U concentration in the aqueous coolant of the first circuit of a nuclear reactor
Authors:A. A. D'yakov  L. I. Men'kin  S. G. Karpechko
Abstract:Conclusions A technique was developed for determining the235U concentration in the aqueous coolant of the first circuit of a nuclear reactor: detection limit sim3·10–12 g/cm3. Using the method in the IVV-2M reactor has shown that with this technique, an operational monitoring of the uranium concentration in the coolant and in the fluids washed from the surface of the first circuit, as well as monitoring other qqueous samples, is possible.Lavsan, which is directly irradiated in a liquid sample and electrochemically etched, can be recommended as a detector. The optimal conditions of etching 180-mgrm-thick lavsan (after irradiation with thermal neutrons to a flux of (1–2)·1016 cm–2) are: 30% aqueous KOH solution, a temperature of (70±0.2)°C, an electric field strength of 20 kV/cm, a frequency of 4 kHz, and an etching time of 100 min.Translated from Atomnaya Énergiya, Vol. 61, No. 5, pp. 334–338, November, 1986.