首页 | 本学科首页   官方微博 | 高级检索  
     


Predicting suspended sediment concentration from nephelometric turbidity in organic‐rich waters
Authors:Christina E Bright  Sarah M Mager  Sophie L Horton
Affiliation:Department of Geography, University of Otago, Dunedin, New Zealand
Abstract:Nephelometric turbidity is an optical index for the side scattering of light caused by fine particles suspended in water. When a mixed composition of suspended inorganic and organic materials, including dissolved organic material, is present, turbidity measurements can be affected by the different optical properties of the organic and inorganic materials present, and different turbidimeters are more or less sensitive to these influences. Two different methods of nephelometric turbidity measurement were assessed (using instruments confirming to two different turbidity standard methods: EPA 180.1 and ISO 7027). We investigated the influence of particulate organic matter and coloured dissolved organic matter on relationships between turbidity and suspended sediment concentration for rivers in diverse Otago catchments, in the South Island of New Zealand. The presence of organic matter and dissolved colour affected turbidity measurement owing to light absorption; however, turbidity measurement following the ISO 7027 standard, which specifies near infrared radiation at wavelengths where organic absorption is very weak, was less affected by organics. As a result, rating equations between suspended sediment and turbidity may be significantly different with ISO 7027 compared with EPA 180.1 methods.
Keywords:nephelometry  particulate organic matter  suspended sediment concentration  turbidity
设为首页 | 免责声明 | 关于勤云 | 加入收藏