首页 | 本学科首页   官方微博 | 高级检索  
     

CO2的浓度含量对超声波气体流量计的精度影响
引用本文:黄雪杰,李晓东,朱士明. CO2的浓度含量对超声波气体流量计的精度影响[J]. 声学技术, 2003, 22(4): 246-248
作者姓名:黄雪杰  李晓东  朱士明
作者单位:同济大学声学所,上海,200092
摘    要:文章设计了实验用以测试CO2的浓度含量对超声波气体流量计测量精度的影响,实验结果表明,由于在流量计中采用了“过零电平检测”、“随机多次测量声时后平均”等技术措施,即使在CO2的浓度较高的情况下,流量计依然可以保持在较高的测量精度。

关 键 词:超声波气体流量计 二氧化碳浓度 测量精度 过零电平检测 色谱仪 随机多次测量声时后平均
文章编号:1000-3630(2003)04-0246-03
修稿时间:2003-04-07

Influence of carbon dioxide concentration on the measurement accuracy of ultrasonic gas flowmeter
HUANG Xue-jie,LI Xiao-dong,ZHU Shi-ming. Influence of carbon dioxide concentration on the measurement accuracy of ultrasonic gas flowmeter[J]. Technical Acoustics, 2003, 22(4): 246-248
Authors:HUANG Xue-jie  LI Xiao-dong  ZHU Shi-ming
Abstract:An experiment has been designed to test the influence of carbon dioxide concentration on the measurement accuracy of ultrasonic gas flowmeter developed in the Institute of Acoustics, Tongji University. The results indicate that, even in case of high concentration of carbon dioxide, the flowmeter still maintains high measurement accuracy due to the techniques employed including zero-crossing detection of electrical level, averaging of multiple transit-time measurements randomly taken, and so forth.
Keywords:ultrasonic gas flowmeter  chromatograph  measurement accuracy  zero-crossing detection of electrical level
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号