首页 | 本学科首页   官方微博 | 高级检索  
     


The effect of forming gas anneal on the oxygen content in bonded copper layer
Authors:C S Tan  K N Chen  A Fan  R Reif
Affiliation:(1) Microsystems Technology Laboratories, Massachusetts Institute of Technology, 02139 Cambridge, MA;(2) IBM T.J. Watson Research Center, 10598 Yorktown Heights, NY
Abstract:Using a combination of copper (Cu) thermocompression bonding and silicon wafer thinning, a face-to-face silicon bi-layer layer stack is fabricated. The oxygen content in the bonded Cu layer is analyzed using secondary ion mass spectrometry (SIMS). Copper-covered wafers that are exposed to the air for 12 h and 12 days prior to bonding exhibit 0.08 at.% and 2.96 at.% of oxygen, respectively. However, prebonding forming gas anneal at 150°C for 15 min on 12-day-old Cu wafers successfully reduces the oxygen content in the bonded Cu layer to 0.52 at.%.
Keywords:Copper  thermocompression bonding  forming gas  three-dimensional integrated circuits (3-D ICs)
本文献已被 SpringerLink 等数据库收录!