首页 | 本学科首页   官方微博 | 高级检索  
     

滤光片对透射式微型X光管谱线影响的MC数值模拟分析
引用本文:李秋实,魏周政,程鹏亮,赵剑锟,杨镜明.滤光片对透射式微型X光管谱线影响的MC数值模拟分析[J].核电子学与探测技术,2017,37(1).
作者姓名:李秋实  魏周政  程鹏亮  赵剑锟  杨镜明
作者单位:1. 核工业二一六大队,新疆乌鲁木齐,830011;2. 核与辐射安全管理中心,贵州,铜仁554300;3. 成都理工大学核技术与自动化工程学院,四川成都,610059
摘    要:现场X射线荧光分析(EDXRF)中,使用滤光片可以有效的降低或消除由原级谱在样品中散射背景,特征谱对待测元素的干扰。论文采用MCNP5程序模拟了加不同厚度Al、Cu、Ag、Kapton滤光片前后的原级谱分布。依据模拟结果,原级X射线谱的谱分布与滤光片的材质和厚度有关。能量低于5ke V的射线对分析是无用的。在能量5~10 ke V的能量谱段,选择Al滤光片较为合适;在能量10~25ke V谱段范围,Ag滤光片相对于另外三种滤光片较为合适。从而为现场X荧光分析仪的研制提供技术支撑。

关 键 词:微型X射线管  现场X射线荧光分析  滤光片  MCNP5

Simulation on The Effect of Filter on Spectral Lines in Transmission Micro X-Ray Tube by MC Method
LI Qiu-shi,WEI Zhou-zheng,CHENG Peng-liang,ZHAO Jian-kun,YANG Jing-ming.Simulation on The Effect of Filter on Spectral Lines in Transmission Micro X-Ray Tube by MC Method[J].Nuclear Electronics & Detection Technology,2017,37(1).
Authors:LI Qiu-shi  WEI Zhou-zheng  CHENG Peng-liang  ZHAO Jian-kun  YANG Jing-ming
Abstract:In the in-situ energy-dispersive X-ray fluorescence analysis(EDXRF),the use of filters can effectively reduce or eliminate the original spectrum in the sample by scattering the background,the characteristic spectrum of the interference of the measured elements.In this paper,the MCNP5 program was used to simulate the original spectrum distributions of Al,Cu,Ag and Kapton filters with different thicknesses.Based on the simulation results,the attenuation of the X-ray fluorescence spectrum is related to the material and thickness of the filter.Ray analysis of energy below 5 keV is useless.In the energy range of 5 ~ 10 keV,it is more appropiiate to select the Al filter;in the energy range of 10 ~25 keV,the Ag filter is more suitable than the other three filters.So the study can provide technical support for the development of X-ray fluorescence analyzer.
Keywords:Miniature X-ray tube  Filter  MCNP5  In-situ energy-dispersive X-ray fluorescence analysis (EDXRF)
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号