Control rod drop hydrodynamic analysis for a pressurized water reactor
Affiliation:1. Nuclear Science and Technology Research Institute, Tehran, Zip code: 14399-51113, Iran;2. Department of Energy Engineering, Sharif University of Technology, Tehran, Zip code: 8639-11365, Iran;1. Dpto. de Sistemas Informáticos y Computación, Universitat Politècnica de València, Camí de Vera s/n, 46022 Valencia, Spain;2. Inst. de Seguridad Industrial, Radiofísica y Medioambiental, Universitat Politècnica de València, Camí de Vera s/n, 46022 Valencia, Spain;3. Iberdrola Ingeniería y Construcción S.A.U., Av. Manoteras, 20. Edificio C, 28050 Madrid, Spain;1. Division of Remote Handling and Robotics, Bhabha Atomic Research Centre, Mumbai 400085, India;2. Homi Bhabha National Institute, Anushaktinagar, Mumbai 400094, India;1. Nuclear Power Plants Authority, Cairo, Egypt;2. Nuclear & Radiation Engineering Department, Alexandria University, Alexandria, Egypt
Abstract:During operation of nuclear power reactors, reactivity initiated accidents can take place such as a control rod drop. If this occurs, the reactivity increases significantly and leads to an enhancement in power, fuel temperature and damage of reactor eventually. Exact assessment of these accidents depends on the hydrodynamic information. In this research, it is tried to simulate the unsteady flow field around the control rod for a pressurized water reactor power plant. In order to simulate the flow field around the control rod inside the guide tube, averaged Navier–Stokes equations accompanied by the layering dynamic mesh strategy have been used. The information exchange between the two computational stationary and moving grids, the computational grid around the control rod and the grid next to the guide tube, has been taken place through the interface. It was concluded that the time duration of control rod to reach the bottom of the core depends on the leakage. It was also observed that the velocity and acceleration of the control rod would be reduced by decreasing leakage flow rate and in certain leakages, the acceleration of the control rod approaches zero due to equilibrium conditions. During this research, a correlation based on the achieved data was proposed which would provide useful information on the relation between the leakage and the time for control rod to reach the bottom of the core.
Keywords:Control rod drop  Pressurized water reactor  Hydrodynamic  CFD  Accident
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号