首页 | 本学科首页   官方微博 | 高级检索  
     


Influence of different luting agents on the stress distributions of implant-supported all-ceramic single crown
Authors:Shaohuai Gao  Min Wang  Haiying Duan  Qing Li  Zhiyong Li
Affiliation:1. Department of Prosthodontics, School and Hospital of Stomatology, Wuhan University, Wuhan, 430079, China
2. Department of Implantology, School and Hospital of Stomatology, Wuhan University, Wuhan, 430079, China
3. Department of Stomatology, Wuhan Central Hospital of China Construction Third Engineering Bureau Co. Ltd, Wuhan, 430079, China
Abstract:The purpose of this study was to investigate the influence of different luting agents on the stress distribution within the crown, abutment and peri-implant bone of implant-supported all-ceramic single crown. A three-dimensional finite element model of an implant-supported single crown for the first premolar of mandible was created by COSMOS 2.85. Resin-modified glass ionomer and two different resin adhesives were used to cement the crown and abutment. Vertical 600 N and horizontal 225 N loads were applied to stimulate the condition of chewing. The stress distributions within the all-ceramic crown, abutment and peri-implant bone were analyzed. The experimental results show that the stress distributions of all-ceramic crown, abutment, implant and peri-implant bone were similar when different luting agents were used. The result of present study indicated that luting agents had no influence on the stress distributions of implant-supported all-ceramic single crown.
Keywords:stress distributions  dental implants  luting agent  all-ceramic
本文献已被 维普 SpringerLink 等数据库收录!