10kV配电线路无功补偿的选择
引用本文:李泳泉,金华芳,胡惜超.10kV配电线路无功补偿的选择[J].电力电容器与无功补偿,2008,29(2).
作者姓名:李泳泉  金华芳  胡惜超
摘    要:介绍了10 kV配电线路的现状和实施无功补偿的必要性,分析提出了10 kV配电线路无功补偿容量选取原则、安装地点选择计算方法,并结合电网发展的需要分析了自动控制的技术需求。采用本文介绍的办法,实地试装了两条线路,取得了理想的补偿效果。

关 键 词:配电线路  无功补偿  并联电容器组  自动控制  保护

Selection of the Reactive Power Compensation for 10 kV Distribution Line
LI Yong-quan,JIN Hua-fang,HU Xi-chao.Selection of the Reactive Power Compensation for 10 kV Distribution Line[J].Power Capacitor $ Reactive Power Compensation,2008,29(2).
Authors:LI Yong-quan  JIN Hua-fang  HU Xi-chao
Abstract:The paper mainly introduced the development of the 10 kV distribution line and the necessity of the reactive power compensation.Combining the demand of auto-control technology with the development of electric network,the selection principle of the reactive power compensation for 10kV distribution line and the install place calculation method of selection were proposed.Using this method,the reactive power compensation devices had been installed on two lines and excellent compensation effects were obtained.
Keywords:Distribution line  Reactive power compensation  Shunt capacitor bank  Auto-control  Protection
本文献已被 万方数据 等数据库收录!