首页 | 本学科首页   官方微博 | 高级检索  
     

双曲冷却塔的脉动风荷载模拟和风致响应
引用本文:鲍侃袁,沈国辉,孙炳楠.双曲冷却塔的脉动风荷载模拟和风致响应[J].浙江大学学报(自然科学版 ),2010,44(5):955-961.
作者姓名:鲍侃袁  沈国辉  孙炳楠
作者单位:1.浙江大学 建筑工程学院,浙江 杭州 310027; 2.浙江大学宁波理工学院 土木建筑工程分院,浙江 宁波 315100
基金项目:国家自然科学基金资助项目(50608063)
摘    要:采用线性滤波法中的自回归模型(AR)法对冷却塔表面空间相关的多点脉动风压时程进行模拟,分析脉动风压在时域和频域上的分布特征,发现准定常假设不够准确.同时采用有限元方法对冷却塔的自振频率分布和模态特征进行讨论,发现冷却塔的自振频率较为密集,前40阶自振频率为1.0~2.2Hz.通过冷却塔在脉动风压作用下的瞬态响应分析,得到冷却塔各响应的时域和频域特征,描述响应中的背景分量和共振分量的分布特点,并探讨AR法中采样间隔的合理取值.通过对有限元瞬态分析的结果分析指出,风致位移响应在塔身颈部附近达到最大,Mises应力响应则在塔底附近达到最大值.

关 键 词:大型双曲冷却塔  风致响应  自回归线性滤波法  时域分析

Numerical simulation of fluctuating wind load and wind induced response of large hyperbolic cooling tower
BAO Kan-yuan,SHEN Guo-hui,SUN Bing-nan.Numerical simulation of fluctuating wind load and wind induced response of large hyperbolic cooling tower[J].Journal of Zhejiang University(Engineering Science),2010,44(5):955-961.
Authors:BAO Kan-yuan  SHEN Guo-hui  SUN Bing-nan
Affiliation:1.College of Civil Engineering and Architecture, Zhejiang University, Hangzhou 310027, China; 2. School of Civil Engineering and Architecture, Ningbo Institute of Technology, Zhejiang University, Ningbo 315100, China
Abstract:An auto regressive (AR) linear filter method was used to simulate the spatial correlative multiple fluctuating wind load on the outside surface of cooling tower. The characteristic of simulation results was analyzed with the time domain and the frequency domain method. Results indicate that quasi steady theory is not appropriate. The distribution of natural frequency and the mode characteristic were calculated through the finite element method. The natural frequencies were densely distributed, and first 40 of them were confined to 1.0~2.2 Hz. The transient analysis was conducted under the fluctuating wind load. Then the various responses of cooling tower in time domain and frequency domain were achieved. The background and the resonant parts were studied respectively, and the appropriate sampling interval was discussed. Transient dynamic analysis results show that the wind induced displacement reaches maximum at someplace close to neck and Mises stress reaches maximum at someplace near the bottom.
Keywords:   large hyperbolic cooling tower  wind-induced response  auto-regressive linear filter method  time domain analysis
本文献已被 CNKI 等数据库收录!
点击此处可从《浙江大学学报(自然科学版 )》浏览原始摘要信息
点击此处可从《浙江大学学报(自然科学版 )》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号