Highly salicylate-selective membrane electrode based on a new thiomacrocyclic Schiff base complex of binuclear copper(II) as neutral carrier
Authors:En-Ping Luo  Ya-Qing Chai  Jian-Yuan Dai
Affiliation:a Chongqing Key Laboratory of Analytical Chemistry, Southwest China Normal University, Chongqing, 400715, China
b Teaching-Research Section of Analytical Medicine Chemistry, Guiyang Nursing Vocational College, Guiyang, 550003, China
Abstract:New binuclear metallic complexes of thiomacrocyclic Schiff base, 3,9,13,19 -tetraphenyl-6,16-dithione-1,11-dithio-4,5,7,8,14,15,17,18-octaazacycloeicosa-3,8,13,18-tetraene binuclear metal(II) M(II)2-TDDOCT] (M = Cu, Co, Ni), were synthesized and their anion response characteristics were investigated. The performances of the electrodes are considerably influenced by the nature of the central metals. The Cu(II) complex-based electrode exhibited a good selectivity to salicylate anion with an anti-Hofmeister selectivity pattern: Sal > ClO4 > SCN > I > Benzoate > Br > Acetate > F > SO32− > NO2 > Cl > NO3 > SO42− > H2PO4. The electrode had an excellent linear response to Sal from 9.0 × 10− 7 to 1.0 × 10− 1 M with a slope of − 59.3 mV per decade,a detection limit of 5.0 × 10− 7 M, and a fast response time within 15 s over the entire concentration series in phosphate buffer solutions of pH 5.0 at 25 °C. Spectroscopic techniques and the influence of lipophilic charged additives on the electrode behavior were used to investigate the response mechanism to Sal. The electrode can be applied to the direct determination of salicylate in human urine and pharmaceutical samples and the results obtained are in accord with the results from a standard method.
Keywords:Salicylate  Ion-selective electrode  3  9  13  19-tetraphenyl-6  16-dithione-1 11-dithio-4  5  7  8  14  15  17  18-octaazacycloeicosa-3  8  13  8-tetraene binuclear copper(II) complex  Neutral carrier
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号