首页 | 本学科首页   官方微博 | 高级检索  
     


Development of correlations for Nusselt number and friction factor for solar air heater with roughened duct having arc-shaped wire as artificial roughness
Authors:S.K. Saini  R.P. Saini
Affiliation:1. Central Building Research Institute, Roorkee 247 667, India;2. Alternate Hydro Energy Centre, Indian Institute of Technology, Roorkee 247 667, India;1. School of Mechanical and Civil Engineering, Shoolini University, Solan, India;2. Department of Mechanical Engineering, DIT University, India;3. Department of Mechanical Engineering, AP Goyal Shimla University, Himachal Pradesh, India;4. Department of Higher Education, Government Senior Secondary School Kalhog, Solan, India;5. Department of Physics and Electronic, Hansraj College, University of Delhi, India;1. Mechanical Engineering Department, Shoolini University, Solan 173229, Himachal Pradesh, India;2. Alternate Hydro Energy Centre, Indian Institute of Technology Roorkee, Roorkee 247667, Uttarakhand, India;3. Mechanical & Industrial Engineering Department, Indian Institute of Technology Roorkee, Roorkee 247667, Uttarakhand, India;1. Department of Mechanical Engineering, IPEC, Ghaziabad, UP, India;2. Department of Mechanical Engineering, National Institute of Technology Hamirpur, HP 177005, India
Abstract:An experimental study has been carried out for enhancement of heat transfer coefficient of a solar air heater having roughened air duct provided with artificial roughness in the form of arc-shape parallel wire as roughness element. Increment in friction factor by provided with such artificial roughness elements has also been studied. The effect of system parameters such as relative roughness height (e/d) and arc angle (α/90) have been studied on Nusselt number (Nu) and friction factor (f) with Reynolds number (Re) varied from 2000 to 17000. Considerable enhancement in heat transfer coefficient has been achieved with such roughness element. Using experimental data correlations for Nusselt number and friction factor have also been developed for such solar air heaters, which gives a good agreement between predicted values and experimental values of Nusselt number and friction factor.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号