首页 | 本学科首页   官方微博 | 高级检索  
     

牡丹花粉中4种重金属含量的测定与分析
引用本文:孙亚真,张孟琴,尤芳芳,王丽莉.牡丹花粉中4种重金属含量的测定与分析[J].食品安全质量检测技术,2021,12(10):4174-4178.
作者姓名:孙亚真  张孟琴  尤芳芳  王丽莉
作者单位:洛阳海关;铜仁学院材料与化学工程学院
摘    要:目的 采用微波消解-原子吸收光谱法/原子荧光光谱法测定牡丹花粉中铅、镉、总汞、总砷含量,探明洛阳农博园地区牡丹花粉中4种重金属污染物状况。方法 选取6个主栽品种牡丹花粉样品,经微波消解后,采用原子吸收光谱法和原子荧光光谱法测定4种重金属污染物含量,并分析和评价测定结果。结果 铅、镉、总汞、总砷在一定浓度范围内线性关系良好,相关系数均大于0.998,方法检出限分别为 0.010、0.003、0.003、0.010 mg/kg,各元素的加标回收率在94.2%~109.4%之间。6个主栽品种牡丹花粉中均不同程度地检出了4种重金属污染物,方差分析结果显示,4种重金属元素含量的变异系数均大于10%,品种间差异均具有统计学意义。结论 本方法准确度高、精密度好。参考相关国家标准,6种牡丹花粉中重金属含量均符合要求,本研究为牡丹花粉资源的综合利用及牡丹花粉产品的开发提供数据支持。

关 键 词:牡丹花粉  重金属污染物  原子吸收  原子荧光
收稿时间:2021/1/12 0:00:00
修稿时间:2021/6/10 0:00:00

Determination and analysis of 4 kinds of heavy metals content in peony pollen
SUN Ya-Zhen,ZHANG Meng-Qin,YOU Fang-Fang,WANG Li-Li.Determination and analysis of 4 kinds of heavy metals content in peony pollen[J].Food Safety and Quality Detection Technology,2021,12(10):4174-4178.
Authors:SUN Ya-Zhen  ZHANG Meng-Qin  YOU Fang-Fang  WANG Li-Li
Affiliation:Luoyang customs
Abstract:Objective The content of lead, cadmium, total mercury and total arsenic in the pollen of peony was determined by microwave digestibility-atomic absorption spectrometry/atomic fluorescence spectrometry, in order to explore the status of 4 kinds of heavy metal pollutants in the pollen of peony in Luoyang agricultural expo park area. Methods The content of lead, cadmium, total mercury and total arsenic in the pollen of peony in 6 main cultivars was determined by microwave digestibility-atomic absorption spectrometry/atomic fluorescence spectrometry, and the determination results were analyzed and evaluated. Results The lead, cadmium, total mercury and total arsenic had a good linear relationship in a certain concentration range, the correlation coefficients were greater than 0.998, the limits of method detection were 0.010,0.003,0.003 and 0.010 mg/kg,The recoveries of each element were between 94.2%~109.4%. The 4 kinds of heavy metal pollutants were detected in the pollen of the 6 main cultivars, and the variance analysis results showed that the variation coefficients of the content of the 4 heavy metal elements were all greater than 10%, and the differences among different cultivars showed statistical significance. Conclusion The method has high accuracy and precision. According to the relevant national standard, the content of heavy metals in the pollen of 6 kinds of peony meets the requirements.This study provides data support for the comprehensive utilization of peony pollen resources and the development of peony pollen products.
Keywords:Peony pollen  Heavy metal pollutants  Atomic absorption  Atomic fluorescence
点击此处可从《食品安全质量检测技术》浏览原始摘要信息
点击此处可从《食品安全质量检测技术》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号