首页 | 本学科首页   官方微博 | 高级检索  
     

双曲线冷却塔爆破拆除切口参数的探讨
引用本文:薛里,张志毅,杨年华.双曲线冷却塔爆破拆除切口参数的探讨[J].工程爆破,2011,17(2):49-52.
作者姓名:薛里  张志毅  杨年华
作者单位:中国铁道科学研究院,北京,100081
摘    要:结合茂名电厂双曲线冷却塔爆破拆除工程实例,分析总结了高大冷却塔的结构特点和失稳倾倒机理.在此基础上,采用力学原理分析了爆破切口圆心角和高度等主要参数的计算方法,对类似工程有理论和实践指导意义.

关 键 词:双曲线冷却塔  爆破拆除  爆破切口参数

DISCUSS OF CUT PARAMETERS FOR BLASTING DEMOLITION OF HYPERBOLIC COOLING TOWERS
XUE Li,ZHANG Zhi-yi,YANG Nian-hua.DISCUSS OF CUT PARAMETERS FOR BLASTING DEMOLITION OF HYPERBOLIC COOLING TOWERS[J].Engineering Blasting,2011,17(2):49-52.
Authors:XUE Li  ZHANG Zhi-yi  YANG Nian-hua
Abstract:According to the blasting demolition practice of a hyperbolic cooling tower in Maoming power plant,its structural features and destabilizing mechanism were analyzed and summarized.On this basis,a method of calculating the main blasting parameters,such as the central angle and height of blasting cut,were put forward by applying mechanics principle,which has guiding significance for similar projects in theory and practice.
Keywords:Hyperbolic cooling tower  Blasting demolition  Blasting cut parameters
本文献已被 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号