首页 | 本学科首页   官方微博 | 高级检索  
     


Ozone Contactor Hydrodynamics
Authors:PE Sanjay Reddy  PE Ron Joost  PE John Heckler
Abstract:Tracer tests were conducted at the 6,000 pounds of ozone per day Tucson, CAP Water Treatment Plant in Tucson, Arizona. The tests were designed to determine T10 values through the contactors at various operating conditions. The tests were modeled using three techniques. Peclet Number was calculated for each of the runs, which would indicate the hydrodynamic conditions inside the ozone contactor. The results indicated that the increase in water flow rate and the number of cells with gas flow increased Peclet Number. The flow rate of liquid seemed to impact the Peclet Number more than gas flow. The headloss in each cell appeared to be important in controlling the distribution of liquid and gas through the cell. A correlation was developed between the product of gas and liquid phase Reynolds Number and Peclet Number.
Keywords:Ozone  Ozone Contactor Hydrodynamics  Models  Gas/Liquid Ratio  Cells in Operation  Gas Distribution  Peclet Number  Dispersion  Gas/Liquid Phase Reynolds Number Correlation