首页 | 本学科首页   官方微博 | 高级检索  
     

600MW亚临界机组停炉不停机逻辑的优化与实现
引用本文:袁艳纯,仇新利.600MW亚临界机组停炉不停机逻辑的优化与实现[J].湖南电力,2009,29(1):27-29.
作者姓名:袁艳纯  仇新利
作者单位:大唐华银金竹山火力发电分公司,湖南,冷水江,417505
摘    要:分析了燃煤机组实现停炉不停机的意义及原设计控制逻辑的潜在危险,并以某600MW亚临界机组为对象进行了停炉不停机逻辑的优化,且取得了成功应用。

关 键 词:MFT  停炉不停机  优化

Optimization and realization of protection logic of boiler tripping without turbine tripping for 600MW subcritical power unit
YUAN Yan-chun,QIU Xin-li.Optimization and realization of protection logic of boiler tripping without turbine tripping for 600MW subcritical power unit[J].Hunan Electric Power,2009,29(1):27-29.
Authors:YUAN Yan-chun  QIU Xin-li
Affiliation:Datang Huaying Jinzhushang Thermal Power Branch Company;Lengshuijiang 417505;China
Abstract:The protection logic of boiler tripping without turbine tripping was analyzed and its latent danger was presented.One boiler tripping without turbine tripping protection logic for 600MW subcritical power unit was optimized and applied successfully,giving reference to similar power units.
Keywords:MFT
本文献已被 CNKI 维普 万方数据 等数据库收录!