首页 | 本学科首页   官方微博 | 高级检索  
     

某660 MW锅炉低温过热器和后屏过热器长期高幅值超温分析及治理
引用本文:邵兴恩,李前宇,祝艳平. 某660 MW锅炉低温过热器和后屏过热器长期高幅值超温分析及治理[J]. 山西电力, 2021, 0(2): 60-64
作者姓名:邵兴恩  李前宇  祝艳平
作者单位:岱海发电有限责任公司;北京京能电力股份有限公司
摘    要:某锅炉进行了低氮燃烧器、节能减排综合升级改造,使锅炉运行工况偏离设计值较大,引起低温过热器、后屏过热器等受热面管壁严重超温.通过对超温点、超温时间统计分析,提出了整改措施.

关 键 词:受热面  壁温  逻辑  氧量  风量

Analysis and Treatment of Long-term High Amplitude Overtemperature of Low-temperature and Rear-plate Superheaters of a 660 MW Boiler
SHAO Xingen,LI Qianyu,ZHU Yanping. Analysis and Treatment of Long-term High Amplitude Overtemperature of Low-temperature and Rear-plate Superheaters of a 660 MW Boiler[J]. Shanxi Electric Power, 2021, 0(2): 60-64
Authors:SHAO Xingen  LI Qianyu  ZHU Yanping
Affiliation:(Daihai Power Generation Co.,Ltd.,Liangcheng,Inner Mongolia 013750,China;Beijing Jingneng Power Co.,Ltd.,Beijing 100124,China)
Abstract:A boiler has undergone comprehensive upgrading,including low-nitrogen burner rectification,energy-saving and emission reduction,causing the results that the boiler operating condition deviates greatly from the designed value and severe overtemperature of the heating surface wall of the low-temperature and rear-plate superheaters and so on.Based on a statistical analysis of overtemperature point and overtemperature time,rectification measures are put forward.
Keywords:heating surface  wall temperature  logic  oxygen  air volume