Kinematic calibration for a hybrid 5DOF manipulator based on 3-RPS in-actuated parallel manipulator |
| |
Authors: | Fan LiangZhi A.Y. Elatta Li XiaoPing |
| |
Affiliation: | (1) Mechanical College, HuaZhong University of Science and Technology, China |
| |
Abstract: | The measurement method is a decisive step for any calibration method. This paper studies the practical performance of a 5DOF manipulator based on a 3-RPS parallel mechanism. By comparing the controlling data that resides in parallel part and serial part at different orientations, a calibration method has been put forward and proved to be applicable. The precision of the calibrated model mainly depends on the number of measurements carried out. The distribution of measurement points also affects the precision and the measurement number could be significantly reduced if uniform distribution were ensured. |
| |
Keywords: | 3-RPS Hybrid manipulator Kinematic calibration |
本文献已被 SpringerLink 等数据库收录! |