首页 | 本学科首页   官方微博 | 高级检索  
     

基于MAX-DOAS的对流层NO2和气溶胶光学厚度遥测反演
引用本文:牟福生,李昂,谢品华,王杨,徐晋,张杰,陈浩,吴丰成.基于MAX-DOAS的对流层NO2和气溶胶光学厚度遥测反演[J].大气与环境光学学报,2015,10(3):231-238.
作者姓名:牟福生  李昂  谢品华  王杨  徐晋  张杰  陈浩  吴丰成
作者单位:(中国科学院安徽光学精密机械研究所环境光学与技术重点实验室, 合肥 230031)
基金项目:国家自然科学基金(40275038)、环保公益性项目(201109007)、国家高技术研究发展计划"863"项目(2014AA06A511;2014AA06A508)、安徽省自然科学基金(1308085QF124)、安徽省科技攻关计划项目(1301022083) 资助
摘    要:随着全球工业化速度加快和人口的增多,大气环境问题日益突出,NO2和气溶胶在大气化学中扮演着重要的角色。地基多轴差分吸收光谱技术(MAX-DOAS)基于被动DOAS原理,近年来已成功应用于大气痕量气体柱浓度和气溶胶光学厚度(AOD)测量方面。本文基于被动DOAS算法对合肥秸秆燃烧期间NO2柱浓度以及气溶胶光学厚度进行了观测,并把对流层柱浓度和臭氧监测仪(Ozone Monitoring Instrument, OMI)结果进行对比;测量的气溶胶光学厚度和太阳光度计(CE318)进行了对比。结果表明,MAX-DOAS测量结果要高于卫星值,11月6日MAX-DOAS测量NO2柱浓度日均值为OMI的1.9倍;二者在无云条件下一致性较好;MAX-DOAS反演AOD和太阳光度计结果相关性在0.9以上。

关 键 词:MAX-DOAS  垂直柱浓度  气溶胶光学厚度  太阳光度计  
收稿时间:2014-04-15
修稿时间:2014-05-19

Measurement and Retrieval of Tropospheric NO2 and Aerosol Optical Depth Based on MAX-DOAS
MOU Fu-Sheng,LI Ang,XIE Pin-Hua,WANG Yang,XU Jin,ZHANG Jie,CHEN Hao,WU Feng-Cheng.Measurement and Retrieval of Tropospheric NO2 and Aerosol Optical Depth Based on MAX-DOAS[J].Journal of Atmospheric and Environmental Optics,2015,10(3):231-238.
Authors:MOU Fu-Sheng  LI Ang  XIE Pin-Hua  WANG Yang  XU Jin  ZHANG Jie  CHEN Hao  WU Feng-Cheng
Affiliation:(Key Laboratory of Environment Optics and Technology, Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Science, Hefei 230031, China)
Abstract:With the development of global industrialization and increasing population, the atmosphere environment has been a serious problem. NO2 and aerosols play an important role in atmosphere chemistry. Ground-based multi axis differential optical absorption spectroscopy(MAX-DOAS) has been successfully applied in the measurements of the trace gas vertical column density(VCD) and aerosol optical depth(AOD). NO2 VCD and AOD were measured based on MAX-DOAS in Hefei City during the open stalk burning period. NO2 VCD was compared with the result of OMI, and results of AOD was compared with sunphometer(CE318). It showed that NO2 concentration measured by MAX-DOAS was 1.9 times higher than that of Ozone Monitoring Instrument(OMI), the maximum is 1.9 times the results of OMI, and both instruments had good accordance during clear days. The correlation coefficient between AOD measured by MAX-DOAS and that by CE318 is larger than 0.9.
Keywords:multi axis differential optical absorption spectroscopy  vertical column density  aerosol optical depth  sunphotometer  
本文献已被 CNKI 等数据库收录!
点击此处可从《大气与环境光学学报》浏览原始摘要信息
点击此处可从《大气与环境光学学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号