摘    要:介绍了基于ATmega16L的漏电火灾报警监控系统,描述了其总体设计方案、下位机的软硬件设计、上位机监控界面的软件设计。采用该系统可实时监测线路中的剩余电流值和温度值,以消除漏电火灾隐患。

关 键 词:ATmega16L  剩余电流  实时监控

Design of Building Electric Leakage Alarm Supervision System Based on ATmega16L
HAN Hui-juan,DONG Guan-jun. Design of Building Electric Leakage Alarm Supervision System Based on ATmega16L[J]. Mechanical Management and Development, 2010, 25(6): 195-197
Authors:HAN Hui-juan  DONG Guan-jun
Affiliation:(College of Information Engineering,Taiyuan University of Technology,Taiyuan 030024,China)
Abstract:The paper introduces an electric leakage alarm supervision system based on ATmega16L.The overall design of the system,the design of hardware and software in slave computer and the design of monitoring platform based on PC are described.The system can be used in real-time monitoring of residual current and temperature to eliminate the electrical fire hazards caused by leakage current.
Keywords:ATmega16L  Residual current  Real-time monitoring