Application of Time Series Hyperspectral Imaging (TS-HSI) for Determining Water Distribution Within Beef and Spectral Kinetic Analysis During Dehydration |
| |
Authors: | Di Wu Songjing Wang Nanfei Wang Pengcheng Nie Yong He Da-Wen Sun Jiansong Yao |
| |
Affiliation: | 1. College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou, 310058, China 2. Food Refrigeration and Computerised Food Technology (FRCFT), School of Biosystems Engineering, University College Dublin, Agriculture & Food Science Centre, National University of Ireland, Belfield, Dublin 4, Ireland 3. Department of Mathematics, Zhejiang University, Hangzhou, 310027, China 4. Management Bureau of Agricultural Machine of Haining, Haining, 314400, China
|
| |
Abstract: | This study was carried out for rapid and noninvasive determination of water distribution within beef during dehydration using time series hyperspectral imaging (TS-HSI). Hyperspectral images (380–1,700 nm) of beef slices were acquired at different periods of dehydration process. The spectra of beef were extracted from the TS-HSI images using image segmentation process. Principal component analysis was conducted to obtain an overview of the systematic spectral variations during dehydration. Instead of the traditional data mining strategies to cope with the large multivariate data structures in the TS-HSI images, the selection of effective wavelengths was conducted for the first time to reduce the computational burden of the TS-HSI data and predigest calibration modeling. On the basis of the effective wavelengths identified by using successive projections algorithm (SPA), three spectral calibration algorithms of partial least squares regression, least squares support vector machines, and multiple linear regression (MLR) were compared. The SPA-MLR model with Spectral Set I was considered to be the best for determining water content of beef slice. The model led to a coefficient of determination ( $ r_V^2 $ ) of 0.953 and root mean square error estimated by cross-validation of 1.280 %. The visualization of water distribution within beef slice during dehydration was finally generated by transferring the quantitative model to each pixel in the image to determine water content in all spots of the beef sample. Kinetic analysis of the TS-HSI images was also conducted for the first time to analyze spectral changes of beef during dehydration. The results demonstrate that TS-HSI has the potential of quantitatively visualizing water content of beef rapidly and noninvasively during dehydration in a reasonable accuracy. |
| |
Keywords: | |
本文献已被 SpringerLink 等数据库收录! |
|