首页 | 本学科首页   官方微博 | 高级检索  
     


Transient experiments from the thermal-hydraulic ADS lead bismuth loop (TALL) and comparative TRAC/AAA analysis
Authors:Weimin Ma   Evaldas Bubelis   Aram Karbojian   Bal Raj Sehgal  Paul Coddington  
Affiliation:aNuclear Power Safety Division, Royal Institute of Technology (KTH), 106 91 Stockholm, Sweden;bLaboratory for Reactor Physics and Systems Behavior, Paul Scherrer Institute, 5232 Villigen PSI, Switzerland
Abstract:TALL is a medium-size experimental facility constructed at KTH, to study the steady-state and transient thermal-hydraulics performance of LBE-cooled reactors, with the primary purpose of supporting the European transmutation demonstration (ETD) using LBE-cooled accelerator-driven systems (ADS). This paper presents the results of transient experiments performed on the TALL test facility, whose aim is to provide a data base for validation of computer codes which may be used for the analysis of the safety of those systems. This paper also presents the results of the post-test calculations, carried out at PSI, using the TRAC/AAA code. The transient experiments performed include the loss of heat sink, the loss of pump, the loss of both primary and secondary flows, overpower, overcooling, heater trip, and the operational transients of start-up and shut-down. The experimental results show the excellent natural circulation performance of a LBE-cooled system which should contribute to a good safety performance. The TRAC/AAA calculations provide results which agree well with the experimental data.
Keywords:
本文献已被 ScienceDirect 等数据库收录!