首页 | 本学科首页   官方微博 | 高级检索  
     


The effect of the hysteresis band on power management strategies in a stand-alone power system
Authors:Dimitris Ipsakis  Spyros Voutetakis  Panos Seferlis  Fotis Stergiopoulos  Simira Papadopoulou  Costas Elmasides
Affiliation:1. Chemical Process Engineering Research Institute (C.P.E.R.I.), Centre for Research and Technology-Hellas (CE.R.T.H.), P.O. Box 60361, 57001 Thermi-Thessaloniki, Greece;2. Department of Chemical Engineering, Aristotle University of Thessaloniki, P.O. Box 1517, 54124 Thessaloniki, Greece;3. Department of Mechanical Engineering, Aristotle University of Thessaloniki, P.O. Box 484, 54124 Thessaloniki, Greece;4. Department of Automation, Alexander Technological Educational Institute of Thessaloniki (A.T.E.I.TH.), P.O. Box 141, 57400 Thessaloniki, Greece;5. Sunlight Systems SA, Neo Olvio, Xanthi 67200, Greece
Abstract:A stand-alone power system that consists of a photovoltaic array and wind generators for the exploitation of renewable energy sources (RES), and that is capable of storing excessive energy in the form of hydrogen via water electrolysis for subsequent use in a polymer electrolyte membrane (PEM) fuel cell is currently being installed at Neo Olvio of Xanthi in Greece. The performance of two power management strategies (PMSs) that utilize a hysteresis band in the operation of the integrated system over a typical 4-month period is assessed. The state-of-charge (SOC) level of the accumulator is the main parameter that governs the operation of the electrolyzer and the fuel cell. The introduction of a hysteresis band in the boundary limits of the SOC of the accumulator provides larger flexibility in the operation of the electrolyzer, the fuel cell, and the accumulator. In this way, the units can be protected from heavy and unnecessary utilization or irregular operation (reduction of frequent start-ups and shut-downs). The simulated results for the implemented PMSs revealed important information about the reliability of the load satisfaction, the total operation time that each subsystem undergoes, as well as about the hydrogen inventory in the integrated system. The study also identified the effect of variation of hysteresis band size on the system performance as an important feature for the development of an integrated control strategy.
Keywords:Renewable energy sources   Stand-alone power system   Hydrogen production   Power management strategies   Hysteresis band   State of charge
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号