首页 | 本学科首页   官方微博 | 高级检索  
     


Concentration of HIx solution by electro-electrodialysis using Nafion 117 for thermochemical water-splitting IS process
Authors:M. Yoshida  N. Tanaka  H. Okuda  K. Onuki
Affiliation:1. Japan Atomic Energy Agency, 4002 Narita-cho, Oarai-machi, Higashiibaraki-gun Ibaraki 311-1393, Japan;2. CHIYODA CORPORATION, 3-13 Moriya-cho, Kanagawa-ku, Yokohama-shi Kanagawa 221-0022, Japan
Abstract:An experimental study of applying electro-electrodialysis (EED) for improved HI concentration in the HIx solution, a mixture of HI–I2–H2O of approximately quasi-azeotropic compositions has been carried out in the conditions of around 90 °C and using Nafion 117 and graphite electrodes. A range of 25–80% increase in initial current efficiency of HI molality in catholyte is measured with the use of EED. In general, the efficiency increases with increasing iodine molality and weight ratio of anolyte solution to catholyte solution. The EED performance degrades in time. In some cases, the HI concentration limits are observed. Electric conductivity of the HIx solution, overvoltage of electrode reaction, and the membrane voltage drop is measured in a temperature range of 20–120 °C. It is found that the EED cell voltage, which is an important cell performance parameter, is governed by the membrane voltage drop.
Keywords:Electro-electrodialysis   HIx solution   Nafion   IS process   Thermochemical hydrogen production