首页 | 本学科首页   官方微博 | 高级检索  
     

The AC losses measurement and analysis of superconducting NbTi CICC for HT-TU superconducting Tokamak
作者姓名:FANG Jin  WENG Pei-De  CHEN Zhuo-Min  CHEN Jing-Lin  WANG Fu-Tang  HAN Zheng-He
作者单位:Applied Superconductivity Research Center,Tsinghua University,Beijing 100084; lnstitute of Plasma Physics,the Chinese Academy of Sciences,Hefei 230031
摘    要:Superconducting TF and PF coils have been measured in SULTAN test facility. Segregated copper strands are included in four NbTi CICC and this is a technical innovation. Two AC losses measurement methods, calorimetric and electromagnetic methods, have been used in the experiments, and a broad frequency range (from 0.05 Hz to 6 Hz) is covered in sample test. The purpose of this experiment was to investigate AC losses of TF and PF CICC conductor including segregated copper and to check the design of PF and TF CICC coated with different resistive barriers (Pb-30Sn-2Sb and Ni plating on NbTi strands).


The AC losses measurement and analysis of superconducting NbTi CICC for HT-TU superconducting Tokamak
FANG Jin,WENG Pei-De,CHEN Zhuo-Min,CHEN Jing-Lin,WANG Fu-Tang,HAN Zheng-He.The AC losses measurement and analysis of superconducting NbTi CICC for HT-TU superconducting Tokamak[J].Nuclear Science and Techniques,2003,14(1).
Authors:Fang Jin  WENG Pei-de  CHEN Zhuo-min  CHEN Jing-lin  WANG Fu-tang  HAN Zheng-he
Abstract:Superconducting TF and PF coils have been measured in SULTAN test facility. Segregated copper strands are included in four NbTi CICC and this is a technical innovation. Two AC losses measurement methods, calorimetric and electromagnetic methods, have been used in the experiments, and a broad frequency range (from 0.05 Hz to 6 Hz) is covered in sample test. The purpose of this experiment was to investigate AC losses of TF and PF CICC conductor including segregated copper and to check the design of PF and TF CICC coated with different resistive barriers (Pb-30Sn-2Sb and Ni plating on NbTi strands).
Keywords:Cable-in-conduit conductor  Coupling loss time constant  Sn and Ni plated conductor  Contact resistance
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号