首页 | 本学科首页   官方微博 | 高级检索  
     


Comparative investigation of antibacterial yet biocompatible Ag-doped multicomponent coatings obtained by pulsed electrospark deposition and its combination with ion implantation
Authors:EI Zamulaeva  AN Sheveyko  AY Potanin  IY Zhitnyak  NA Gloushankova  IV Sukhorukova  NV Shvindina  SG Ignatov  EA Levashov  DV Shtansky
Affiliation:1. National University of Science and Technology \"MISIS\", Leninsky Prospect 4, Moscow 119049, Russia;2. N.N. Blokhin Medical Research Center of Oncology of Ministry of Health, Kashirskoe Shosse 24, Moscow 115478, Russia;3. State Research Center for Applied Microbiology and Biotechnology, Obolensk, Moscow Region 142279, Russia;4. Moscow State University, Department of Geocryology, Moscow 119992, Russia
Abstract:The aim of this work is to obtain antibacterial yet biocompatible coatings using pulsed electrospark deposition (PED). For this purpose new composite electrodes were fabricated from reaction mixtures Ti–C–20%Fe-10%Ca3(PO4)2–3.4%Mg–X%Ag with different amount of antibacterial component (X = 0, 0.5, 1.0, 1.5 and 2.0 at% of Ag) using self-propagating high-temperature synthesis method. The electrodes consisted of TiC grains surrounded by TiFe2 and TiFeP intermetallic matrix, CaO and MgO inclusions, and Ag-based phase. The influence of Ag content on the electrode mass transfer kinetics was studied by comparing the total substrate weight gain and electrode mass loss during PED. The structure, elemental composition, and surface roughness of coatings were studied by means of X-ray diffraction, scanning electron microscopy, and optical profilometry. The coatings were characterized in terms of Ag+ ion release, mechanical and electrochemical properties, as well as biocompatibility. The antibacterial characteristics of Ag-doped PED coatings were compared with those obtained by PED using Ag-free electrode and then implanted with Ag+ ions. The results indicated that an increase in the Ag content in electrode leads to a decrease in electrode erosion and substrate weight gain, but the efficiency of the PED process increases. Doping with a small amount of Ag (≤ 1 at%) resulted in 100% antibacterial effect against both gram-positive S. aureus and gram-negative E. сoli bacteria. In addition, the dynamics of МС3Т3-Е1 cell proliferation on the surface of PED coatings with 0.6–0.7 at% of Ag was similar to that in control samples, hereby indicating their biocompatibility. The coating biological characteristics were discussed based on the results of Ag+ ion release and electrochemical tests.
Keywords:A  Films  A  Implantation  E  Biomedical applications  Pulsed electrospark deposition
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号