首页 | 本学科首页   官方微博 | 高级检索  
     

用Excel计算高层建筑冷风渗透热负荷
引用本文:谭湘阳. 用Excel计算高层建筑冷风渗透热负荷[J]. 建筑热能通风空调, 2001, 20(2): 37-40
作者姓名:谭湘阳
作者单位:新疆建筑设计研究院
摘    要:介绍用Execl电子表格软件的方法,来计算20层以上的建筑冷风渗透热负荷,以简化计算过程,提高精确性。

关 键 词:冷风渗透 Execl电子表格 热负荷 风压 高层建筑

Calculating Heat Load for Infiltration in High-Rise Buildings with Microsoft Excel
By Tan Xiangyang. Calculating Heat Load for Infiltration in High-Rise Buildings with Microsoft Excel[J]. Building Energy & Environment, 2001, 20(2): 37-40
Authors:By Tan Xiangyang
Affiliation:By Tan Xiangyang
Abstract:When we caculate the heat load of high-rise building ,we must consider that the heat load calculation of high-rise building's is different from that of low-rise building's.The heat load for infiltration through windows and doors have to be included because the heat load varies graduatelly due to the windows position height and the wind velocity outside.If we caculate it based on the design handbook,the process will be complicated,so we can caculate the heat load for infiltration with Microsoft Excel,the software about automatic table can simplify the process and makes the data accurately.
Keywords:pressure caused by wind   pressure caused by temperature   cold air infiltration   direction coefficient  Excel  automatic filling-blank  