Caustic Failure of Thermal Insulated Tubing in Steam Flooding |
| |
摘 要: |
|
收稿时间: | 1997-01-28 |
Caustic Failure of Thermal Insulated Tubing in Steam Flooding |
| |
Authors: | Aiping XIAN Yiyin SAN Dun ZHANG and Yikang WANGHeping SUN |
| |
Affiliation: | Aiping XIAN,Yiyin SAN,Dun ZHANG and Yikang WANG(Institute of Metal Research,Chinese Academy of Sciences,Shenyang,China)Heping SUN(Liaohe Oil Field Machinery Plant,Panjin,China) |
| |
Abstract: | The coupling of the pre-stressed thermal insulated tubing string broke down inside the steam flooding wells, after the tubing were used in high temperature and high pressure steam for about two years. With further check, it was found that most of the weld joints between the inner and outer tubing also cracked. The failure analysis for the accidents has been carried out by the analysis of chemical composition for the steels, microstructure observation, mechanical property tests, and the investigation of the service environment etc.. The results show that the early damage of the pre-stressed thermal insulated tubing string is mainly induced by the caustic stress corrosion, which can be strengthened by an unstable microstructure of the coupling serviced at high temperature for a long time. Moreover, the high pre-stress design on the thermal insulated pipe for the cyclic steam injection may be not suitable to the situation of steam flooding, which would result in the weld joint cracking. |
| |
Keywords: | |
本文献已被 CNKI 等数据库收录! |
| 点击此处可从《材料科学技术学报》浏览原始摘要信息 |
|
点击此处可从《材料科学技术学报》下载全文 |
|