某600 MW机组锅炉异常MFT分析
引用本文:苗长信,姚常青.某600 MW机组锅炉异常MFT分析[J].电力建设,2008,29(8):81-0.
作者姓名:苗长信  姚常青
作者单位:( 山东电力研究院, 济南市, 250002)
摘    要:某600MW机组锅炉发生了异常MFT 事故。文章分析了锅炉发生MFT 事故的主要原因, 总结出是由于煤质差、稳燃脆弱、炉内结渣、火检调试欠佳等问题导致事故发生, 并提出了防范措施, 为防止类似事故发生及事故处理提供参考。

关 键 词:煤粉锅炉  煤质  结渣  火检  MFT  故障分析  
收稿时间:2010-01-25
修稿时间:2010-01-25

Analysis of 600 MW Unit Boiler Abnormal MFT
MIAO Chang-xin,YAO Chang-qing.Analysis of 600 MW Unit Boiler Abnormal MFT[J].Electric Power Construction,2008,29(8):81-0.
Authors:MIAO Chang-xin  YAO Chang-qing
Abstract:Abnormal MFT fault occurred on a 600 MW unit boiler. Through analyzing, it is concluded that the causes are low quality coal, fragile combustion, slagging inside the boiler, poor flame inspection and adjustment, etc. Preventive measures are also proposed to prevent similar accident from happening and provide reference for accident handling.
Keywords:pulverized-coal-firing boiler  coal quality  slagging  flame inspection  MFT fault analysis