首页 | 本学科首页   官方微博 | 高级检索  
     

一起主变压器压力释放阀喷油原因分析及处理
引用本文:余青山.一起主变压器压力释放阀喷油原因分析及处理[J].湖北水力发电,2014(5):62-63.
作者姓名:余青山
作者单位:清江水电开发有限责任公司,湖北宜昌443000
摘    要:介绍了水布垭电厂压力释放阀动作的原因、开关断开后的处理经过、随油温变化变压器的体积计算及油位计校验方法,提出了主变压器出现非电气故障时的防范措施。

关 键 词:主变压器  压力释放阀  非电气故障  油位计  校验

Analysis and Treatment of an Oil Ejection Accident from Pressure Relief Valve in the Main Transformer
YU Qingshan.Analysis and Treatment of an Oil Ejection Accident from Pressure Relief Valve in the Main Transformer[J].Hubei Water Power,2014(5):62-63.
Authors:YU Qingshan
Affiliation:YU Qingshan (Hubei Qingjiang Hydroelectric Development Co. , Ltd. , Yichang 443000, China, China)
Abstract:The causes for an oil ejection accident from the pressure relief valve in the main transformer in Shuibuya hy -dropower station are analyzed .The reason for the action of pressure relief valves , the processing procedure after the switch turns off , the volume calculation method for transformers which can adjust with the oil temperature , and the chec-king technique for oil level meters are discussed .At last, prevention measures are suggested for such non-electrical faults of the main transformer .
Keywords:main transformer  pressure relief valve  non-electrical fault  oil level meter  checking
本文献已被 CNKI 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号