摘    要:介绍了水布垭电厂压力释放阀动作的原因、开关断开后的处理经过、随油温变化变压器的体积计算及油位计校验方法,提出了主变压器出现非电气故障时的防范措施。

关 键 词:主变压器  压力释放阀  非电气故障  油位计  校验

Analysis and Treatment of an Oil Ejection Accident from Pressure Relief Valve in the Main Transformer
YU Qingshan. Analysis and Treatment of an Oil Ejection Accident from Pressure Relief Valve in the Main Transformer[J]. Hubei Water Power, 2014, 0(5): 62-63
Authors:YU Qingshan
Affiliation:YU Qingshan (Hubei Qingjiang Hydroelectric Development Co. , Ltd. , Yichang 443000, China, China)
Abstract:The causes for an oil ejection accident from the pressure relief valve in the main transformer in Shuibuya hy -dropower station are analyzed .The reason for the action of pressure relief valves , the processing procedure after the switch turns off , the volume calculation method for transformers which can adjust with the oil temperature , and the chec-king technique for oil level meters are discussed .At last, prevention measures are suggested for such non-electrical faults of the main transformer .
Keywords:main transformer  pressure relief valve  non-electrical fault  oil level meter  checking