摘    要:介绍了 4 5 0 0m3 /h制氧机水冷塔氮气量减少对水冷塔及其他系统工况的影响 ,通过降低分子筛纯化器再生气量和再生气压力以及提高膨胀机制冷量的措施 ,对制氧机进行了调整运行工况的有效尝试

关 键 词:空分设备  水冷塔  氮气  减少  工况  尝试
文章编号:1009-9425(2004)03-0042-02
修稿时间:2003年10月16

Reducing nitrogen added to the water cooling tower and attempting to maintain the operating conditions
Li Zhan,jun.Reducing nitrogen added to the water cooling tower and attempting to maintain the operating conditions[J].Cryogenic Technology,2004(3):42-43.
Authors:Li Zhan  jun
Abstract:The effects of reducing nitrogen added to the water cooling tower in relation to 4500m 3/h oxygen plant on the operating conditions of the water cooling tower and the other systems are described. The operating conditions of the oxygen plant are adjusted by reducing the gas flow capacity for regeneration of molecular sieve purifiers and the pressure of regenerated gas and increasing the refrigerating capacity produced by the expander. As a result, the attempt is satisfactory