首页 | 本学科首页   官方微博 | 高级检索  
     

钨铜混合粉中铜的测定
引用本文:赵淑丽,叶毅岚. 钨铜混合粉中铜的测定[J]. 中国钨业, 2004, 19(3): 42-44
作者姓名:赵淑丽  叶毅岚
作者单位:大余县伟良钨业有限公司,江西,大余,341500
摘    要:试样用浓盐酸及过氧化氢分解,不经沉淀分离钨而进行铜的测定。实验表明,加氨水可以消除钨的干扰,从而确定了碘量法快速测定钨铜混合料中铜的分析方法。

关 键 词:钨铜    碘量法
文章编号:1009-0622(2004)03-0042-03
修稿时间:2003-08-22

Determination of Copper Content in the Mixed Tungsten Copper Powder
ZHAO Shu-li,YE Yi-lan. Determination of Copper Content in the Mixed Tungsten Copper Powder[J]. China Tungsten Industry, 2004, 19(3): 42-44
Authors:ZHAO Shu-li  YE Yi-lan
Abstract:s: The test sample is decomposed by strong hydrochloric acid and peroxide, the copper content isdetermined before the tungsten is deposited and separated. Experiment indicates that after adding ammonia the tungsten′s disturbance can be eliminated so the copper content can be determined by iodine method in the mixed tungsten copper powder.
Keywords:tungsten copper  copper  dermination  
本文献已被 CNKI 维普 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号