首页 | 本学科首页   官方微博 | 高级检索  
     


Analysis of turbine generator steady-state reactances for load conditions
Authors:Shin'ichi Wakui  Kazumasa Ide  Miyoshi Takahashi  Gustavo Montoya  Futoshi Hiyama  Yasuomi Yagi
Abstract:This paper describes variations of turbine generator steady-state reactances for load conditions. When the turbine generator is of small size, magnetic saturation of the stator and rotor core is a problem. Therefore, it is important to understand the variations of the reactances for load conditions. The reactances of a 592-MVA turbine generator are calculated with d- and q-axis equations considering magnetic saturation and two-dimensional numerical magnetic field analysis. The results are as follows. (1) The equivalent synchronous reactances considering cross-magnetizing are smaller than the original synchronous reactances for load conditions. (2) Numerical values of the d- and q-axis mutual reactance and the field and q-axis mutual reactance are at their maximum when the d-axis linkage flux is nearly equal to the q-axis linkage flux under constant voltage. (3) The d-axis synchronous reactance drops with increasing reactive power under constant voltage and active power, but the q-axis synchronous reactance increases. (4) The variation of the equivalent d-axis synchronous reactance with increasing reactive power is similar to that of the d-axis synchronous reactance, but the variation of the equivalent q-axis synchronous reactance is different from that of the q-axis synchronous reactance. © 1998 Scripta Technica. Electr Eng Jpn, 123(3): 73–83, 1998
Keywords:turbine generator  d- and q-axis equations  magnetic field analysis  magnetic saturation  reactance
设为首页 | 免责声明 | 关于勤云 | 加入收藏