首页 | 本学科首页   官方微博 | 高级检索  
     


The use of continuous i.v. sedation is associated with prolongation of mechanical ventilation
Authors:MH Kollef  NT Levy  TS Ahrens  R Schaiff  D Prentice  G Sherman
Affiliation:Department of Medicine, Washington University School of Medicine, St. Louis, MO 63110, USA.
Abstract:STUDY OBJECTIVE: To determine whether the use of continuous i.v. sedation is associated with prolongation of the duration of mechanical ventilation. DESIGN: Prospective observational cohort study. SETTING: The medical ICU of Barnes-Jewish Hospital, a university-affiliated urban teaching hospital. PATIENTS: Two hundred forty-two consecutive ICU patients requiring mechanical ventilation. INTERVENTIONS: Patient surveillance and data collection. MEASUREMENTS AND RESULTS: The primary outcome measure was the duration of mechanical ventilation. Secondary outcome measures included ICU and hospital lengths of stay, hospital mortality, and acquired organ system derangements. A total of 93 (38.4%) mechanically ventilated patients received continuous i.v. sedation while 149 (61.6%) patients received either bolus administration of i.v. sedation (n=64) or no i.v. sedation (n=85) following intubation. The duration of mechanical ventilation was significantly longer for patients receiving continuous i.v. sedation compared with patients not receiving continuous i.v. sedation (185+/-190 h vs 55.6+/-75.6 h; p<0.001). Similarly, the lengths of intensive care (13.5+/-33.7 days vs 4.8+/-4.1 days; p<0.001) and hospitalization (21.0+/-25.1 days vs 12.8+/-14.1 days; p<0.001) were statistically longer among patients receiving continuous i.v. sedation. Multiple linear regression analysis, adjusting for age, gender, severity of illness, mortality, indication for mechanical ventilation, use of chemical paralysis, presence of a tracheostomy, and the number of acquired organ system derangements, found the adjusted duration of mechanical ventilation to be significantly longer for patients receiving continuous i.v. sedation compared with patients who did not receive continuous i.v. sedation (148 h [95% confidence interval: 121, 175 h] vs 78.7 h [95% confidence interval: 68.9, 88.6 h]; p<0.001). CONCLUSION: We conclude from these preliminary observational data that the use of continuous i.v. sedation may be associated with the prolongation of mechanical ventilation. This study suggests that strategies targeted at reducing the use of continuous i.v. sedation could shorten the duration of mechanical ventilation for some patients. Prospective randomized clinical trials, using well-designed sedation guidelines and protocols, are required to determine whether patient-specific outcomes (eg, duration of mechanical ventilation, patient comfort) can be improved compared with conventional sedation practices.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号