摘    要:为提高管壳式换热器管子的管端和管板胀接接头的可靠性,分析了胀管过程的受力情况,认为GB151-89规定的胀管间隙和孔带尺寸偏大,实际应用中应加以注意,并提出胀接前最佳间隙C的计算公式。

关 键 词:换热器  管板胀接  可靠性分析  接头  管壳式
修稿时间:2000年1月26日

Analysis of Reliability of the Expansion Joint Between the Tube and the Tube Sheet of the Tube-and-shell Heat Exchanger
Li Yonghua.Analysis of Reliability of the Expansion Joint Between the Tube and the Tube Sheet of the Tube-and-shell Heat Exchanger[J].Sulphur Phosphorus & Bulk Materials Handling Related Engineering,2000(4):6-8.
Authors:Li Yonghua
Affiliation:Jiangsu Provincial Safety Test Center Institute of Boilers and Pressure Vessels .Nanjing 210002
Abstract:In order to improve the reliability of the expansion joint between the tube end and the tube sheet of the tube-and-shell heat exchanger,the author analyzes the stress in the course of tube expansion, thinks that the clearance between expansible tubes and the distance between holes,stipulated by GB151 - 89,are a bit too large and should be noted in practical application, and proposes a calculation formula for C-the optimum clearance before expansion jointing.
Keywords:heat exchanger  tube sheet  expansion jointing  reliability  analysis