首页 | 本学科首页   官方微博 | 高级检索  
     

浙江某工业废水处理厂升级改造运行效果解析
引用本文:张晓霞,熊仁久,周家中,杨忠启,吴迪,韩文杰.浙江某工业废水处理厂升级改造运行效果解析[J].中国给水排水,2021(5):37-42,50.
作者姓名:张晓霞  熊仁久  周家中  杨忠启  吴迪  韩文杰
作者单位:中国市政工程华北设计研究总院有限公司;浙江省桐乡市水务集团;青岛思普润水处理股份有限公司
基金项目:国家水体污染控制与治理科技重大专项(2017ZX07106005);青岛西海岸新区自主创新重大专项(2019-20)。
摘    要:浙江某工业废水处理厂升级改造,采用AAO—MBBR复合生物膜工艺,在未新增建设用地和扩建池容的基础上,日处理量由3×104m3/d提高至6×104m3/d。改造后实际运行出水COD、TP、NH3-N和TN浓度分别为(37.7±6.61)、(0.09±0.03)、(0.25±0.14)和(5.87±1.54)mg/L,出水水质稳定达到一级A标准。实际监测表明,在好氧MBBR区存在TN去除现象,约占TN总去除量的10.36%。系统内的优势硝化菌属为硝化螺旋菌属Nitrospira,其在悬浮载体生物膜和活性污泥中的相对丰度分别为8.98%和0.92%,悬浮载体的投加使硝化细菌得到有效富集;反硝化菌在生物膜中的占比为7.94%,为悬浮载体同步硝化反硝化(SND)效果的发生提供了微观保证,提高了TN去除率。

关 键 词:工业废水处理厂  升级改造  MBBR工艺  同步硝化反硝化  悬浮载体

Analysis on Upgrading and Retrofitting Effect of an Industrial Wastewater Treatment Plant in Zhejiang
ZHANG Xiao-xia,XIONG Ren-jiu,ZHOU Jia-zhong,YANG Zhong-qi,WU Di,HAN Wen-jie.Analysis on Upgrading and Retrofitting Effect of an Industrial Wastewater Treatment Plant in Zhejiang[J].China Water & Wastewater,2021(5):37-42,50.
Authors:ZHANG Xiao-xia  XIONG Ren-jiu  ZHOU Jia-zhong  YANG Zhong-qi  WU Di  HAN Wen-jie
Affiliation:(North China Municipal Engineering Design&Research Institute Co.Ltd.,Tianjing 300074,China;Zhejiang Tongxiang WWTP,Tongxiang 314500,China;Qingdao Spring Water Treatment Co.Ltd.,Qingdao 266555,China)
Abstract:An industrial wastewater treatment plant in Zhejiang was upgraded by a combined process consisting of anaerobic/anoxic/oxic activated sludge process and moving bed biofilm reactor(AAO-MBBR).Without changing the footprint and increasing the reactor volume,the treatment capacity increased from 30000 m3/d to 60000 m3/d after retrofitting.Concentrations of COD,TP,NH3-N and TN in effluent were(37.7±6.61)mg/L,(0.09±0.03)mg/L,(0.25±0.14)mg/L and(5.87±1.54)mg/L,respectively,which met the first class A standard.Actual operation data indicated that TN removal existed in the aerobic MBBR zone(accounting for 10.36%of total TN removal).Nitrospira was the dominant nitrifying bacteria in the system,and its relative abundance in the suspended carrier and activated sludge was 8.98%and 0.92%,respectively,indicating that the addition of suspended carrier could effectively enrich the nitrifying bacteria.The proportion of denitrifying bacteria on biofilm was 7.94%,which created a micro environment for the occurrence of simultaneous nitrification and denitrification(SND)in the suspended carrier and improved the TN removal efficiency.
Keywords:industrial wastewater treatment plant  upgrading and retrofitting  moving bed biofilm reactor  simultaneous nitrification and denitrification  suspended carrier
本文献已被 CNKI 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏