摘    要:垃圾焚烧发电厂属小机组电厂,一般机组出力为9 MW~25 MW不等,针对这样小容量机组的电厂,其全厂电气主接线形式与大容量火力发电机组相比有其自身的特点。本文结合深圳市宝安区白鸽湖垃圾焚烧发电厂电气主接线的实际设计范例,介绍了小容量机组电气主接线形式选择的设计思路,并提出了自己观点进行探讨。

关 键 词:垃圾焚烧发电厂  电气主接线设计

Discussion of Main Electrical Connection Type and Operation Mode of Waste Incineration Power Plant
ZHANG Ying.Discussion of Main Electrical Connection Type and Operation Mode of Waste Incineration Power Plant[J].Non-ferrous Metallurgical Equipment,2014(3):12-16.
Authors:ZHANG Ying
Affiliation:ZHANG Ying (Electrical and Automation Department, China ENFI Engineering Corporation, Beijing 100038, China)
Abstract:The power of the assembling units fluctuates from 9 to 25 MW, in waste incineration power plant. For these small -load plants, which main electrical connection has its own characteristics, compared with the large power plants. Taking an example of main electrical connection of the waste incineration power plant in Shenzhen Baoan district, this thesis introduces design thought of main electrical connection for small - load plants, and presents the author' s own viewpoint.