首页 | 本学科首页   官方微博 | 高级检索  
     

SCR法烟气脱硝后空气预热器堵塞及应对措施
引用本文:惠润堂,韦飞,王宝德,杨爱勇.SCR法烟气脱硝后空气预热器堵塞及应对措施[J].中国电力,2014,47(10):110-112.
作者姓名:惠润堂  韦飞  王宝德  杨爱勇
作者单位:1. 国电环境保护研究院,江苏 南京 210031;2. 华北电力设计院,北京 100011
摘    要:选择性催化还原(SCR)法是目前燃煤电厂常用的烟气脱硝技术,火电厂加装SCR脱硝装置后易出现空气预热器(空预器)腐蚀和堵塞问题。通过某电厂实际案例,分析了SCR脱硝装置投运后对空预器运行造成的影响,并在分析原因的基础上给出应对措施。为控制空预器压差不继续增加,该电厂低负荷运行时SCR脱硝系统停止喷氨,正常运行时减少喷氨量,并在停炉后将空预器冷端换热元件更换为镀搪瓷元件。采取措施后运行一年多来,空预器压差正常,未出现严重的堵塞现象。

关 键 词:燃煤电厂  烟气脱硝  选择性催化还原(SCR)  空气预热器  
收稿时间:2014-05-28

Analysis and Prevention of SCR DeNOx-Caused Air Preheater Clogging
HUI Run-tang,WEI Fei,WANG Bao-de,YANG Ai-yong.Analysis and Prevention of SCR DeNOx-Caused Air Preheater Clogging[J].Electric Power,2014,47(10):110-112.
Authors:HUI Run-tang  WEI Fei  WANG Bao-de  YANG Ai-yong
Affiliation:1. State Power Environmental Protection Research Institute, Nanjing 210031, China;2. North China Electric Power Design Institute, Beijing 100011, China
Abstract:The selective catalytic reduction(SCR) is commonly used for flue gas denitrification in coal-fired power plants. Corrosion and clogging tend to happen in the air preheaters after the SCR denitrification device is installed. In the case study of a power plant, the analysis of the impacts of the SCR denitrication device on the air preheater is conducted and some measures against the corrosion and clogging are proposed accordingly. To control the pressure difference of the air preheater no longer increasing, the ammonia is stopped spraying into the SCR denitrification device during low load operation while it is reduced during normal load operation. In addition, the heat exchange part of the air preheater heater is changed to an enameled one during the boiler shutdown. In more than a year of operation since then, the pressure difference has been normal and no severe clogging has ever happened.
Keywords:coal-fired power plant  flue gas denitrafication  SCR  air preheater
本文献已被 万方数据 等数据库收录!
点击此处可从《中国电力》浏览原始摘要信息
点击此处可从《中国电力》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号