固相微萃取-气相色谱三重四极杆质谱对自来水中卤代烃类消毒副产物的检测
引用本文:康萌,邹雪,曹京昊,王鸿梅,沈成银,储焰南.固相微萃取-气相色谱三重四极杆质谱对自来水中卤代烃类消毒副产物的检测[J].大气与环境光学学报,2017,12(4):276-282.
作者姓名:康萌  邹雪  曹京昊  王鸿梅  沈成银  储焰南
作者单位:(1中国科学院合肥物质科学研究院医学物理与技术中心,医学物理与技术安徽省重点实验室,安徽 合肥 230031;2.中国科学院安徽光学精密机械研究所,安徽 合肥 230031)
基金项目:国家自然科学基金(21577145, 21477132)资助
摘    要:利用固相微萃取-气相色谱三重四极杆质谱技术(SPME-GC-TQMS)对合肥市科学岛不同区域自来水进行了检测,研究了该地区自来水中部分消毒副产物(DBPs)的存在情况,以及DBPs含量与自来水封存时间的关系,并利用SPME-GC-TQMS对煮沸的自来水进行检测,考察煮沸方式去除卤代烃类消毒副产物的有效性。结果表明: 科学岛自来水中存在三氯甲烷、一溴二氯甲烷和二溴一氯甲烷等多种卤代烃类DBPs,且来源于不同建筑物的自来水中DBPs含量差异高达3倍;自来水在水管内存储时间越长,卤代烃类DBPs浓度越低;自来水经过煮沸处理后,大多数卤代烃DBPs可有效去除,但三氯甲烷仅降为原自来水中含量的30.2%,仍大量存在于凉开水中。

关 键 词:消毒副产物  固相微萃取-气相色谱三重四极杆质谱  自来水  
收稿时间:2016-03-21
修稿时间:2016-03-31

Detection of Disinfection By-Products in Tap Water by Solid Phase Microextraction Gas Chromatography Triple Quadrupole Mass Spectrometry
KANG Meng,ZOU Xue,CAO Jing-Hao,WANG Hong-Mei,SHEN Cheng-Yin,CHU Yan-Nan.Detection of Disinfection By-Products in Tap Water by Solid Phase Microextraction Gas Chromatography Triple Quadrupole Mass Spectrometry[J].Journal of Atmospheric and Environmental Optics,2017,12(4):276-282.
Authors:KANG Meng  ZOU Xue  CAO Jing-Hao  WANG Hong-Mei  SHEN Cheng-Yin  CHU Yan-Nan
Affiliation:(1 Anhui Province Key Laboratory of Medical Physics and Technology, Center of Medical Physics and Technology, Hefei Institutes of Physical Science, Chinese Academy of Science, Hefei 230031, China; 2.Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Science, Hefei 230031, China)
Abstract:Solid phase microextraction gas chromatography triple quadrupole mass spectrometry (SPME-GC-TQMS) was used to detect the tap water from different areas in Hefei Science Island. It was used to study the existence of partial disinfection by-products (DBPs) in tap water and the relation between DBPs concentration and storage time of tap water in tube. SPME-GC-TQMS was also used to investigate the effectiveness of boiling method for the removal of halogen hydrocarbon disinfection byproduct. The results indicated that tap water in the Science Island contained chloroform, bromodichloromethane, dibromochloromethane and other halogenated hydrocarbon DBPs. In addition, their difference of concentration in tap water from different buildings was up to three times. The longer the storage time of tap water, the lower the concentration of DBPs. The results indicated that most of DBPs in tap water can be effectively removed after boiled. But the chloroform concentration only decreased to 30.2% of the original concentration of tap water.
Keywords:disinfection by-products  solid phase microextraction gas chromatography triple quadrupole mass spectrometry  tap water  
点击此处可从《大气与环境光学学报》浏览原始摘要信息
点击此处可从《大气与环境光学学报》下载全文