首页 | 本学科首页   官方微博 | 高级检索  
     

125 MW汽轮发电机组不对中故障的诊断
引用本文:王荻,梁超,严灿萱. 125 MW汽轮发电机组不对中故障的诊断[J]. 广东电力, 1999, 12(5): 30-31
作者姓名:王荻  梁超  严灿萱
作者单位:1. 广东省电力试验研究所,广东,广州,510600
2. 黄埔发电厂,广东,广州,510731
摘    要:通过对黄埔发电厂3号机组(125 MW)汽轮机振动故障的特征分析,诊断出汽轮机低压转子和发电机转子中心不正是振动故障的原因,并采取相应措施消除故障.通过分析中心不正导致振动的机理,探讨了不对中故障的诊断判据.它对同型125 MW机组的故障诊断具有参考意义.

关 键 词:汽轮发电机组  不对中  故障诊断
修稿时间:1999-03-03

Misalignment fault diagnosis for 125 MW steam turbo-unit
WANG Di,LIANG Chao,YAN Can-xuan. Misalignment fault diagnosis for 125 MW steam turbo-unit[J]. Guangdong Electric Power, 1999, 12(5): 30-31
Authors:WANG Di  LIANG Chao  YAN Can-xuan
Abstract:By analyzing thecharacteristics of steam turbine vibration fault of Unit 3 in Huangpu Power Plant,themisalignment between the turbine low-pressure rotor and generator rotor was found to bethe cause of the vibration,and corresponding measures were taken to eliminate thefault.The mechanism of vibration caused by misalignment is analyzed and decision basis formisalignment fault diagnosis is discussed as well.
Keywords:steam turbo generating unit  misalignment  fault diagnosis  