五星酒店室内泳池空调设计与节能实例分析
引用本文:梁晓媚,杨素云,王培才,许艳.五星酒店室内泳池空调设计与节能实例分析[J].广东土木与建筑,2012(2):51-54.
作者姓名:梁晓媚  杨素云  王培才  许艳
作者单位:广东省建工设计公司
摘    要:近年五星星级酒店配建的室内游泳池日趋流行,文中针对其空调设计的特点,以江苏某酒店为例分析其热湿负荷的计算、防结露防锈蚀措施,并提出相关的运行策略和节能手段。

关 键 词:酒店室内泳池  热湿负荷  除湿  运行策略  节能

Analysis of Air-conditioning Design and Energy Saving Measures of Indoor Swimming Pool in Five-star Hotels
Liang Xiaomei Yang Suyun Wang Peicai Xu Yan.Analysis of Air-conditioning Design and Energy Saving Measures of Indoor Swimming Pool in Five-star Hotels[J].Guangdong Architecture Civil Engineering,2012(2):51-54.
Authors:Liang Xiaomei Yang Suyun Wang Peicai Xu Yan
Affiliation:Liang Xiaomei Yang Suyun Wang Peicai Xu Yan (Guangdong Province Construction Design Company Guangzhou 510240,China)
Abstract:Indoor swimming pools are gradually popular in five-star hotels.Based on the characteristics of its air-conditioning designs,this paper takes one hotel in Jiangsu for example,the calculation of heat loads and humid loads,preventions from dew and corrosion are presented.And running measures and energy saving measures are introduced.
Keywords:indoor swimming pools in hotels  heat loads and humid loads  moisture  running measures  energy saving