摘    要:本文对三坐标测量机上进行同轴度测量出现的误判现象进行了定量分析,分析了某产品横轴支架同轴度加工误差的成因,并提出了利用三坐标测量数据来消除横轴支架同轴度误差的解决方案。

关 键 词:同轴度误差  坐标测量CMM

Coaciality Error Measurement and Analysis of Transverse Axis Support
Zhang Xiaomin,Wang Zheng. Coaciality Error Measurement and Analysis of Transverse Axis Support[J]. Fire Control Radar Technology, 2010, 39(3): 85-88
Authors:Zhang Xiaomin  Wang Zheng
Affiliation:( Xi'an Electronic Engineering Research Institute, Xi'an 710100)
Abstract:Quantitative analysis of mis-judgment during coaxiality measurement with a three-coordinate measurement machine (CMM) is conducted, cause of eoaxiality processing error in a transverse axis support structure is analyzed, and solution to eliminate coaxiality error of the transverse axis support structure by using of three-coordinate measurement data is provided.