黄坛口水电站溢洪道弧形闸门的安全检测与更新改造设计
引用本文:费修渔. 黄坛口水电站溢洪道弧形闸门的安全检测与更新改造设计[J]. 大坝与安全, 2002, 0(4): 52-55
作者姓名:费修渔
作者单位:乌溪江水电厂,浙江,衢州,324000
摘    要:黄坛口水电站建于50年代,设计和施工时在总体布置上没有考虑弧形闸门的检修条件,使闸门一直处于挡水状态,存在相当多的隐患。通过对弧形闸门和启闭机的安全检测,分析了弧形闸门和启闭机存在的缺陷,提出了更新改造设计方案。

关 键 词:黄坛口水电站  溢洪闸门  安全检测  更新改造
文章编号:1671-1092(2002)04-0052-04
修稿时间:2002-04-03

Modification design and safety check for spillway radial gate in Huangtankou Hydropower Station
by Fei Xiuyu//Wuxijiang Hy -dropow er Plant. Modification design and safety check for spillway radial gate in Huangtankou Hydropower Station[J]. Large Dam & Safety, 2002, 0(4): 52-55
Authors:by Fei Xiuyu//Wuxijiang Hy -dropow er Plant
Affiliation:by Fei Xiuyu//Wuxijiang Hy -dropow er Plant
Abstract:Huanatankou Hydropower Station was built in1950s,being short of experience and specification at its design and construction stage then,the check and re pair conditions for radial gate were not considerdd in general arrangement ,so much perils left for op eration.In this paper,defects of gate and hoist have been analyzed by checking its safety condition and mod-ification scheme is presented.
Keywords:Huangtankou Hydropower Station  spillway gate  safety check  rehabilitation  
本文献已被 CNKI 维普 万方数据 等数据库收录!