首页 | 本学科首页   官方微博 | 高级检索  
     

含内嵌卯口耗能器的榫卯节点抗震性能试验研究
引用本文:陆伟东,吴伟强,施程凯,刘杏杏.含内嵌卯口耗能器的榫卯节点抗震性能试验研究[J].土木与环境工程学报,2022,44(2):30-37.
作者姓名:陆伟东  吴伟强  施程凯  刘杏杏
作者单位:南京工业大学 土木工程学院, 南京 211816
基金项目:国家自然科学基金(51678298)
摘    要:针对木结构榫卯节点抗震加固和性能提升的需求,提出采用内嵌卯口耗能器增强榫卯节点性能的技术,并制作了包括未增强、单层增强及双层增强的5组缩尺榫卯节点模型.通过开展抗震性能试验研究,对不同厚度、层数的卯口耗能器增强榫卯节点与未增强榫卯节点的抗震性能进行对比,分析了不同参数的卯口耗能器对榫卯节点抗震性能指标的影响.结果 表明...

关 键 词:木结构  内嵌卯口耗能器  榫卯节点  抗震性能
收稿时间:2021/7/8 0:00:00

Experimental study on seismic performance of mortise-tenon joint with embedded dampers
LU Weidong,WU Weiqiang,SHI Chengkai,LIU Xingxing.Experimental study on seismic performance of mortise-tenon joint with embedded dampers[J].Journal of Civil and Environmental Engineering,2022,44(2):30-37.
Authors:LU Weidong  WU Weiqiang  SHI Chengkai  LIU Xingxing
Affiliation:College of Civil Engineering, Nanjing Tech University, Nanjing 211816, P. R. China
Abstract:In response to the needs of seismic reinforcement and performance improvement of the mortise-tenon joints in wood structure buildings, this paper proposed the use of embedded dampers to enhance the performance of the mortise-tenon joints and made five groups of scaled mortise-tenon joint models including unreinforced, single-layer reinforced and double-layer reinforced embedded dampers. Through the test research of seismic performance, the seismic performance of the mortise-tenon joints with different thickness and number of layers was compared with that of the joints without reinforcement, and the seismic performance of embedded dampers with different parameters on the joints of mortise-tenon were analyzed. The results show that the embedded dampers have the characteristics of two-way energy dissipation, multi-point yielding and strong designability, which can greatly improve the seismic performance of the mortise-tenon joints and effectively suppress the tenon pulling phenomenon of joints; compared with the unreinforced joint, the embedded dampers-enhanced joints has a small increase in bearing capacity, the energy consumption capacity has been greatly improved and the initial stiffness has been greatly improved by more than 50 times; the steel plate thickness and the number of layers of the embedded dampers are the main factors affecting the seismic performance of the mortise-tenon joints, and the thickness has the greatest impact on the mechanical properties of the mortise-tenon joints strengthened by the embedded dampers; the double-layer embedded dampers is more effective than the single-layer energy dissipater.
Keywords:wood structure  embedded dampers  mortise-tenon joint  seismic performance
点击此处可从《土木与环境工程学报》浏览原始摘要信息
点击此处可从《土木与环境工程学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏