首页 | 本学科首页   官方微博 | 高级检索  
     


Electrical Parameter Measurement System of the Ion Source for EAST Neutral Beam Injector
Authors:Zhongjun Tian  Chundong Hu  Sheng Liu  Yongjian Xu
Affiliation:1. Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, 230031, China
Abstract:Neutral beam injection (NBI) is recognized as one of the most effective means of plasma heating. A virtual instrument (VI) has been designed to provide electrical parameter measurement for the ion source of EAST-NBI. The VI is written using the National Instruments LabVIEW graphical programming language. All data acquisition (DAQ) is accomplished using ADLINK DAQ hardware interface and Task-oriented DAQ Driver. The VI can measure filament voltage, filament current, arc voltage, arc current and accelerating voltage etc. The data obtained from the VI are feedback of the ion source operation state and helpful to direct the operation parameter optimization of the ion source.
Keywords:
本文献已被 SpringerLink 等数据库收录!