首页 | 本学科首页   官方微博 | 高级检索  
     

反渗透系统故障分析及处理
引用本文:宁良荣. 反渗透系统故障分析及处理[J]. 工业水处理, 2009, 29(11)
作者姓名:宁良荣
作者单位:启东市供电公司,江苏南通,226200
摘    要:针对启东市供电公司发电工区反渗透水处理系统脱盐率下降、压差升高、产水量下降等问题进行了现场调查研究,分析了原因,并提出了相应的处理措施,最终使问题得以解决.

关 键 词:反渗透  脱盐  水处理

Malfunction analysis and treatment of reverse osmosis system
Ning Liangrong. Malfunction analysis and treatment of reverse osmosis system[J]. Industrial Water Treatment, 2009, 29(11)
Authors:Ning Liangrong
Abstract:The problems, such as desalting rate goes down, pressure difference goes up and the quantity of produced water gets lower, in the reverse osmosis system at the electricity generating area of Qidong Power Supply Co. have been investigated. Their causes are analyzed and corresponding treatment measures are put forward. Finally, the problems are solved.
Keywords:reverse osmosis  desalination  water treatment
本文献已被 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号