引用本文:缪玉玲,丁勇,谢源源.长江流域居住建筑不同供暖模式下的负荷特性分析[J].暖通空调,2020,50(1):70-77,49.
作者姓名:缪玉玲  丁勇  谢源源
作者单位:重庆大学国家级低碳绿色建筑国际联合研究中心绿色建筑与人居环境营造教育部国际合作联合实验室
基金项目:国家重点研发计划项目“既有公共建筑室内物理环境改善关键技术研究与示范”(编号:2016YFC0700705);国家自然科学基金项目“基于室内声-光-热物理环境下的人体综合反应模型研究”(编号:51978095)
摘    要:通过分析长江流域冬季供暖特点,采用建筑环境动态负荷分析软件DeST-h对该地区典型城市重庆居住建筑在连续供暖和间歇供暖2种供暖模式下的冬季逐时热负荷进行了计算,分析了2种供暖模式下的负荷分布特性。连续供暖的热负荷总体水平较低,波动较小,且与室外空气温度呈负相关,而间歇供暖的热负荷波动较大,具体表现为开始阶段热负荷较大,而后迅速降低并稳定。据此进一步分析了该负荷特性对长江流域居住建筑的空气源热泵机组选型及运行调节的影响。分析得出:按照夏季供冷工况进行设备选型,机组名义工况下的制热量能满足连续供暖的最大热负荷需求和间歇供暖稳定阶段的热负荷需求;连续供暖条件下部分负荷率主要分布在25%~75%之间,机组的运行调节可采用定容量压缩机台数控制方式;间歇供暖条件下部分负荷率主要分布在50%~100%之间,建议采用变容量调节方式。

关 键 词:长江流域  居住建筑  连续供暖  间歇供暖  负荷特性  设备容量  运行调节

Load characteristics of residential buildings under different heating modes in Yangtze River Basin
Miao Yuling,Ding Yong,Xie Yuanyuan.Load characteristics of residential buildings under different heating modes in Yangtze River Basin[J].Journal Heating Ventilating and Airconditioning,2020,50(1):70-77,49.
Authors:Miao Yuling  Ding Yong  Xie Yuanyuan
Abstract:By analysing the heating characteristics of the Yangtze River Basin in winter, calculates the hourly heating loads of a residential building in Chongqing under continuous and intermittent heating modes by using the building environment dynamic load analysis software DeST-h, and analyses the load distribution characteristics of the two heating modes. The continuous heating load is low, with small fluctuations, and has a negative correlation with outdoor air temperature. While the intermittent heating load fluctuates greatly, and the heating load is large at the beginning and then rapidly decreases and stabilizes. Analyses the influence of load characteristics on the selection and operation adjustment of air-source heat pump units in residential buildings in the Yangtze River Basin. The results show that the heating capacity under the nominal working condition of the unit selected according to the summer cooling conditions can meet the maximum heating load demand of continuous heating and the intermittent heating load demand in the stable stage. The partial load rates under continuous heating conditions are mainly distributed between 25% and 75%, so the operation can be adjusted by the number of fixed-capacity compressors. While the partial load rates under intermittent heating conditions are mainly distributed between 50% and 100%, it is recommended to adopt the adjustment method of variable capacity.
Keywords:Yangtze River Basin  residential building  continuous heating  intermittent heating  load characteristic  equipment capacity  operation adjustment