FSSS在240 t/h纯燃煤气锅炉上的应用研究
引用本文:童伟. FSSS在240 t/h纯燃煤气锅炉上的应用研究[J]. 冶金动力, 2008, 0(3): 48-52
作者姓名:童伟
作者单位:攀枝花新钢钒能源动力中心,四川,攀枝花,617062
摘    要:根据新钢钒热电厂240t/h锅炉炉膛安全监控系统的实施应用情况,阐述了FSSS系统在大型纯燃煤气锅炉上的应用方式及使用经验,提高了燃气锅炉的安全管理水平和防范特重大事故的能力。

关 键 词:燃气锅炉  安全  自动化
文章编号:1006-6764(2008)03-0048-05
修稿时间:2007-12-04

Application of FSSS in 240 t/h Gas Fired Boiler
TONG Wei. Application of FSSS in 240 t/h Gas Fired Boiler[J]. Metallurgical Power, 2008, 0(3): 48-52
Authors:TONG Wei
Affiliation:TONG Wei (Energy Sources and Power Center, New Steel-Vanadium Co., Ltd., Panzhihua, Sichnan 617062, China)
Abstract:Based on the application status of the safety monitor system for 240 t/h boiler hearth of the heat power plant of New Steel-Vanadium Co., Ltd, the application mode and experience of the FSSS system in a large gas fired boiler were presented. It increased safety management level of the gas fired boiler and capability to prevent major accidents.