首页 | 本学科首页   官方微博 | 高级检索  
     


Imaging damage evolution in a small particle metal matrix composite
Authors:Evans,Phaneuf,&   Boyd
Affiliation:Department of Materials and Metallurgical Engineering, Queen's University, Kingston, ON, Canada, K7L 3N6,;Fibics Incorporated, Ottawa, ON, Canada, K1A 0G1
Abstract:It is difficult to study effectively microstructural damage in metal matrix composites (MMCs) due to artefacts arising from traditional metallographic sample preparation techniques. The sectioning and imaging capabilities of the focused ion beam (FIB) microscope provide an excellent method for studying damage accumulation in MMCs.
The capabilities of the FIB system have been used to carry out a study of damage evolution in a powder-processed/hot-extruded Al2080/SiCp MMC. Microvoid damage is found to be preserved accurately during FIB sectioning, allowing measurements of the fraction of decohered particles and the void area fraction. These microscopic damage measurements are correlated with the macroscopic damage parameter, D , as determined by density measurements.
Using transmission electron microscopy, the evolution of dislocation structures at the SiC–matrix interfaces has been examined. A previously unreported decohesion mechanism has been observed.
Keywords:Damage accumulation    focused ion beam microscopy    metal matrix composite    transmission electron microscopy
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号